欢迎访问《人工晶体学报》官方网站,今天是 分享到:

人工晶体学报 ›› 2000, Vol. 29 ›› Issue (3): 285-289.

• • 上一篇    下一篇

金刚石膜热沉金属化Ti/Ni/Au体系的研究

潘存海;徐英惠;王少岩;崔文秀;杜素梅;蔡云虹;刁习刚;何奇宇   

  1. 河北省科学院激光研究所,石家庄050081
  • 出版日期:2000-03-15 发布日期:2021-01-20
  • 基金资助:
    河北省科技攻关项目

Study on Adhesion of Ti/Ni/Au Multilayers on Diamond Wafer

PAN Cun-hai;XU Ying-hui;WANG Shao-yan;CUI Wen-xiu;DU Su-mei;CAI Yun-hong;DIAO Xi-gang;HE Qi-yu   

  • Online:2000-03-15 Published:2021-01-20

摘要: 利用电子束蒸镀实现了Ti/Ni/Au多层膜在CVD金刚石膜上的金属化,并研究了预处理和后处理工艺对多层膜在基底上结合的影响,发现高温预处理对多层膜和基底的结合有明显的改善.参照国标GJB 126-86进行了热循环试验,未发现多层膜从金刚石膜脱落.利用背散射谱研究了Ti/Ni/Au金属化体系在真空中分别加热400℃和500℃,60 min 金属层的热稳定性.结果发现:优化工艺金刚石膜和金属层间的良好结合和稳定性满足金刚石膜热沉应用的要求.

关键词: CVD;金刚石膜;金属化

Abstract: Ti/Ni/Au multilayers have been deposited by electron beam evaporation, to metallize CVD diamond wafers. The effect of pre-treatment and post-treatment on adhesion of the multi-layers to the substrates was investigated, and it was found, introducing a pre-fire at elevated temperatures, the adhesion could be improved significantly. Thermal cycling experiments were accomplished according to the Chinese national standard (GJB 126-86), and the multi-layers were not peeled off from the diamond wafers. Rutherford back-scattering spectroscopy (RBS) had been used to characterize the stability of the Ti/Ni/Au metallization scheme at 400℃, 500℃ for 60 min in vacuum. In conclusion, the good adhesion and the stability of the optimized processing between the diamond and the metal-layers can meet the required of the diamond application as heat sink.

Key words: Ti/Ni/Au multilayers have been deposited by electron beam evaporation, to metallize CVD diamond wafers. The effect of pre-treatment and post-treatment on adhesion of the multi-layers to the substrates was investigated, and it was found, introducing a pre-fire at elevated temperatures, the adhesion could be improved significantly. Thermal cycling experiments were accomplished according to the Chinese national standard (GJB 126-86), and the multi-layers were not peeled off from the diamond wafers. Rutherford back-scattering spectroscopy (RBS) had been used to characterize the stability of the Ti/Ni/Au metallization scheme at 400℃, 500℃ for 60 min in vacuum. In conclusion, the good adhesion and the stability of the optimized processing between the diamond and the metal-layers can meet the required of the diamond application as heat sink.

中图分类号: